Review





Similar Products

98
Sartorius AG streptavidin biosensors
Streptavidin Biosensors, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Octet+Streptavidin+(SA)+Biosensor/pm42900781-222-11-16
Average 98 stars, based on 1 article reviews
streptavidin biosensors - by Bioz Stars, 2026-11
98/100 stars
  Buy from Supplier

96
Sartorius AG octet anti-penta-his (his1k) biosensors
Octet Anti Penta His (His1k) Biosensors, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Octet+Anti-Penta-HIS+(HIS1K)+Biosensors/custom%40bio-layer-interferometry-his1k-biosensors%4042945275
Average 96 stars, based on 1 article reviews
octet anti-penta-his (his1k) biosensors - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

95
Sartorius AG streptavidin coated sax2 biosensors
TEDs were immobilized on the biosensor through the SpyTag003-SpyCatcher003 reaction. (A) Experimental procedure for the “Assay 1: Binding analysis” ( and ). Biotinylated SpyCatcher003 was immobilized on streptavidin-coated <t>SAX2</t> biosensors through the biotin-streptavidin interaction, followed by conjugation of SpyTag003-fused TED. (B) Experimental procedure for the “Assay 2: Covalent cross-linking analysis” ( and ). SpyCatcher003 was immobilized on AR2G biosensors through amine-coupling chemistry, followed by conjugation of SpyTag003-fused TED.
Streptavidin Coated Sax2 Biosensors, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Octet+High+Precision+Streptavidin+2%2E0+(SAX2)+Biosensors/pmc13685950-310-0-3
Average 95 stars, based on 1 article reviews
streptavidin coated sax2 biosensors - by Bioz Stars, 2026-11
95/100 stars
  Buy from Supplier

95
Sartorius AG ar2g biosensors
TEDs were immobilized on the biosensor through the SpyTag003-SpyCatcher003 reaction. (A) Experimental procedure for the “Assay 1: Binding analysis” ( and ). Biotinylated SpyCatcher003 was immobilized on streptavidin-coated SAX2 biosensors through the biotin-streptavidin interaction, followed by conjugation of SpyTag003-fused TED. (B) Experimental procedure for the “Assay 2: Covalent cross-linking analysis” ( and ). SpyCatcher003 was immobilized on <t>AR2G</t> biosensors through amine-coupling chemistry, followed by conjugation of SpyTag003-fused TED.
Ar2g Biosensors, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Octet+Amine+Reactive+2nd+Generation+(AR2G)+Biosensors/pmc13685950-321-21-23
Average 95 stars, based on 1 article reviews
ar2g biosensors - by Bioz Stars, 2026-11
95/100 stars
  Buy from Supplier

95
Sartorius AG ar2g amine
TEDs were immobilized on the biosensor through the SpyTag003-SpyCatcher003 reaction. (A) Experimental procedure for the “Assay 1: Binding analysis” ( and ). Biotinylated SpyCatcher003 was immobilized on streptavidin-coated SAX2 biosensors through the biotin-streptavidin interaction, followed by conjugation of SpyTag003-fused TED. (B) Experimental procedure for the “Assay 2: Covalent cross-linking analysis” ( and ). SpyCatcher003 was immobilized on <t>AR2G</t> biosensors through amine-coupling chemistry, followed by conjugation of SpyTag003-fused TED.
Ar2g Amine, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Octet+Amine+Reactive+2nd+Generation+(AR2G)+Biosensors/pm42900969-97-4-16
Average 95 stars, based on 1 article reviews
ar2g amine - by Bioz Stars, 2026-11
95/100 stars
  Buy from Supplier

96
Sartorius AG octet high precision streptavidin sax biosensors
TEDs were immobilized on the biosensor through the SpyTag003-SpyCatcher003 reaction. (A) Experimental procedure for the “Assay 1: Binding analysis” ( and ). Biotinylated SpyCatcher003 was immobilized on streptavidin-coated SAX2 biosensors through the biotin-streptavidin interaction, followed by conjugation of SpyTag003-fused TED. (B) Experimental procedure for the “Assay 2: Covalent cross-linking analysis” ( and ). SpyCatcher003 was immobilized on <t>AR2G</t> biosensors through amine-coupling chemistry, followed by conjugation of SpyTag003-fused TED.
Octet High Precision Streptavidin Sax Biosensors, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Octet+High+Precision+Streptavidin+(SAX)+Biosensors/pm42892450-41-0-10
Average 96 stars, based on 1 article reviews
octet high precision streptavidin sax biosensors - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

96
Sartorius AG octet high precision streptavidin (sax) biosensors
TEDs were immobilized on the biosensor through the SpyTag003-SpyCatcher003 reaction. (A) Experimental procedure for the “Assay 1: Binding analysis” ( and ). Biotinylated SpyCatcher003 was immobilized on streptavidin-coated SAX2 biosensors through the biotin-streptavidin interaction, followed by conjugation of SpyTag003-fused TED. (B) Experimental procedure for the “Assay 2: Covalent cross-linking analysis” ( and ). SpyCatcher003 was immobilized on <t>AR2G</t> biosensors through amine-coupling chemistry, followed by conjugation of SpyTag003-fused TED.
Octet High Precision Streptavidin (Sax) Biosensors, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Octet+High+Precision+Streptavidin+(SAX)+Biosensors/custom%40bio-layer-interferometry-sax-biosensors%4042892450
Average 96 stars, based on 1 article reviews
octet high precision streptavidin (sax) biosensors - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

96
Sartorius AG anti penta his his1k biosensors
(A) Fixed amino acid residues for MESSI-based deimmunization of LuxSit-i. The structure of LuxSit-i (shown in blue and red) with its luciferin substrate (shown in green) is generated by Alphafold-3. The color on LuxSit-i denotes the number of overlapping NMP-predicted HLA-DRB1*15:01 epitopes at each amino acid position. Fixed amino acid residues are depicted as yellow-colored spheres. (B) Sequence identity of MESSI-generated LuxSit-i variants relative to the parental LuxSit-i. (C) Structural metrics of MESSI-generated LuxSit-i variants. (D) Comparison of epitope density between parental LuxSit-i and a MESSI-generated variant, MESSI-D2. All structures were generated by AlphaFold-3. Color denotes the number of overlapping NMP-predicted HLA-DRB1*15:01 epitopes at each amino acid position. (E) Experimental validation of luminescence from MESSI-generated LuxSit-i variants. Gene fragments encoding the parental and MESSI-designed proteins were synthesized and used as linear DNA template for in vitro RNA transcription and protein translation (IVTT). Afterwards, the reaction product was purified with a nickel spin column to remove the His-tagged IVTT machinery. A final concentration of 25 µM of diphenylterazine (DTZ) was added to the purified proteins. Luminescence was recorded on a plate reader every minute over 2 hr. (F) Peak luminescence recorded within 2 hours after DTZ addition. “No template” denotes the negative control condition where no DNA template was added to the IVTT reaction. Error bars, standard deviation. n = 3 replicates. A two sided unpaired t-test with welch’s correction is calculated between no-target condition and each of the MESSI designs and parent. **, p < 0.01; ****, p < 0.0001. (G) Computational workflow for designing a deimmunized binder against PD-1 using MESSI coupled with BindCraft. In particular, MESSI is inserted at the end of the original BindCraft workflow to replace the soluble MPNN inverse folding model to design sequences against the optimized structures. (H) Structural metrics of MESSI-generated variants of anti-PD-1 binder. (I) Comparison of epitope density between the parental anti-PD-1 binder and a MESSI-generated variant, MESSI-D4. All structures were generated by AlphaFold-3. Blue colors denote a binder region that does not contain NMP predicted epitopes. Red color denotes binder regions with NMP-predicted HLA-DRB1*15:01 epitopes greater than 0. White color denotes the PD-1, the target protein for the designed binder. (J) Strep-tagged minibinders are produced with Genscript IVTT kit. After the production, the binders are purified with streptavidin beads and eluted in 1 mL of PBS. The dot plots show the concentration (expression) fold-change (FC) of the MESSI-generated binders relative to the parental binder designed by BindCraft. (K) Bio-Layer Interferometry (BLI) binding curves for measuring the binding parameters of MESSI-designed anti-PD-1 binders against the target PD-1 protein. The assay was performed at 30 °C and at 1,000 rpm. His-tagged PD-1 protein was firstly immobilized onto <t>HIS1K</t> biosensor on Octet RED384. Binders was applied at a concentration of 1 µM as an analyte for association and dissociation steps for 150 seconds and 30 seconds respectively. PA denotes the parent binder. (L) Equilibrium dissociation constant (K d ) of anti-PD-1 binder variants. K d was derived from the association (K a ) and dissociation (K dis ) rate constants measured from the five concentration scan BLI curves. Error bars represent the 95% confidence interval of the fitted K d . Differences in K d were assessed by a two-sided z-test using moving-block bootstrap standard errors of the global fit (85 seconds blocks, 1,000 resamples; Holm-corrected for comparisons). **, p<0.01
Anti Penta His His1k Biosensors, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Octet+Anti-Penta-HIS+(HIS1K)+Biosensors/bio_rxiv__64898__2026__10__09__758136-222-18-21
Average 96 stars, based on 1 article reviews
anti penta his his1k biosensors - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

99
Cytiva Europe spr biosensor biacore 3000
(A) Fixed amino acid residues for MESSI-based deimmunization of LuxSit-i. The structure of LuxSit-i (shown in blue and red) with its luciferin substrate (shown in green) is generated by Alphafold-3. The color on LuxSit-i denotes the number of overlapping NMP-predicted HLA-DRB1*15:01 epitopes at each amino acid position. Fixed amino acid residues are depicted as yellow-colored spheres. (B) Sequence identity of MESSI-generated LuxSit-i variants relative to the parental LuxSit-i. (C) Structural metrics of MESSI-generated LuxSit-i variants. (D) Comparison of epitope density between parental LuxSit-i and a MESSI-generated variant, MESSI-D2. All structures were generated by AlphaFold-3. Color denotes the number of overlapping NMP-predicted HLA-DRB1*15:01 epitopes at each amino acid position. (E) Experimental validation of luminescence from MESSI-generated LuxSit-i variants. Gene fragments encoding the parental and MESSI-designed proteins were synthesized and used as linear DNA template for in vitro RNA transcription and protein translation (IVTT). Afterwards, the reaction product was purified with a nickel spin column to remove the His-tagged IVTT machinery. A final concentration of 25 µM of diphenylterazine (DTZ) was added to the purified proteins. Luminescence was recorded on a plate reader every minute over 2 hr. (F) Peak luminescence recorded within 2 hours after DTZ addition. “No template” denotes the negative control condition where no DNA template was added to the IVTT reaction. Error bars, standard deviation. n = 3 replicates. A two sided unpaired t-test with welch’s correction is calculated between no-target condition and each of the MESSI designs and parent. **, p < 0.01; ****, p < 0.0001. (G) Computational workflow for designing a deimmunized binder against PD-1 using MESSI coupled with BindCraft. In particular, MESSI is inserted at the end of the original BindCraft workflow to replace the soluble MPNN inverse folding model to design sequences against the optimized structures. (H) Structural metrics of MESSI-generated variants of anti-PD-1 binder. (I) Comparison of epitope density between the parental anti-PD-1 binder and a MESSI-generated variant, MESSI-D4. All structures were generated by AlphaFold-3. Blue colors denote a binder region that does not contain NMP predicted epitopes. Red color denotes binder regions with NMP-predicted HLA-DRB1*15:01 epitopes greater than 0. White color denotes the PD-1, the target protein for the designed binder. (J) Strep-tagged minibinders are produced with Genscript IVTT kit. After the production, the binders are purified with streptavidin beads and eluted in 1 mL of PBS. The dot plots show the concentration (expression) fold-change (FC) of the MESSI-generated binders relative to the parental binder designed by BindCraft. (K) Bio-Layer Interferometry (BLI) binding curves for measuring the binding parameters of MESSI-designed anti-PD-1 binders against the target PD-1 protein. The assay was performed at 30 °C and at 1,000 rpm. His-tagged PD-1 protein was firstly immobilized onto <t>HIS1K</t> biosensor on Octet RED384. Binders was applied at a concentration of 1 µM as an analyte for association and dissociation steps for 150 seconds and 30 seconds respectively. PA denotes the parent binder. (L) Equilibrium dissociation constant (K d ) of anti-PD-1 binder variants. K d was derived from the association (K a ) and dissociation (K dis ) rate constants measured from the five concentration scan BLI curves. Error bars represent the 95% confidence interval of the fitted K d . Differences in K d were assessed by a two-sided z-test using moving-block bootstrap standard errors of the global fit (85 seconds blocks, 1,000 resamples; Holm-corrected for comparisons). **, p<0.01
Spr Biosensor Biacore 3000, supplied by Cytiva Europe, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Biacore/bio_rxiv__64898__2026__10__14__759113-42-5-9
Average 99 stars, based on 1 article reviews
spr biosensor biacore 3000 - by Bioz Stars, 2026-11
99/100 stars
  Buy from Supplier

97
Sartorius AG ni nta biosensors
(A) Fixed amino acid residues for MESSI-based deimmunization of LuxSit-i. The structure of LuxSit-i (shown in blue and red) with its luciferin substrate (shown in green) is generated by Alphafold-3. The color on LuxSit-i denotes the number of overlapping NMP-predicted HLA-DRB1*15:01 epitopes at each amino acid position. Fixed amino acid residues are depicted as yellow-colored spheres. (B) Sequence identity of MESSI-generated LuxSit-i variants relative to the parental LuxSit-i. (C) Structural metrics of MESSI-generated LuxSit-i variants. (D) Comparison of epitope density between parental LuxSit-i and a MESSI-generated variant, MESSI-D2. All structures were generated by AlphaFold-3. Color denotes the number of overlapping NMP-predicted HLA-DRB1*15:01 epitopes at each amino acid position. (E) Experimental validation of luminescence from MESSI-generated LuxSit-i variants. Gene fragments encoding the parental and MESSI-designed proteins were synthesized and used as linear DNA template for in vitro RNA transcription and protein translation (IVTT). Afterwards, the reaction product was purified with a nickel spin column to remove the His-tagged IVTT machinery. A final concentration of 25 µM of diphenylterazine (DTZ) was added to the purified proteins. Luminescence was recorded on a plate reader every minute over 2 hr. (F) Peak luminescence recorded within 2 hours after DTZ addition. “No template” denotes the negative control condition where no DNA template was added to the IVTT reaction. Error bars, standard deviation. n = 3 replicates. A two sided unpaired t-test with welch’s correction is calculated between no-target condition and each of the MESSI designs and parent. **, p < 0.01; ****, p < 0.0001. (G) Computational workflow for designing a deimmunized binder against PD-1 using MESSI coupled with BindCraft. In particular, MESSI is inserted at the end of the original BindCraft workflow to replace the soluble MPNN inverse folding model to design sequences against the optimized structures. (H) Structural metrics of MESSI-generated variants of anti-PD-1 binder. (I) Comparison of epitope density between the parental anti-PD-1 binder and a MESSI-generated variant, MESSI-D4. All structures were generated by AlphaFold-3. Blue colors denote a binder region that does not contain NMP predicted epitopes. Red color denotes binder regions with NMP-predicted HLA-DRB1*15:01 epitopes greater than 0. White color denotes the PD-1, the target protein for the designed binder. (J) Strep-tagged minibinders are produced with Genscript IVTT kit. After the production, the binders are purified with streptavidin beads and eluted in 1 mL of PBS. The dot plots show the concentration (expression) fold-change (FC) of the MESSI-generated binders relative to the parental binder designed by BindCraft. (K) Bio-Layer Interferometry (BLI) binding curves for measuring the binding parameters of MESSI-designed anti-PD-1 binders against the target PD-1 protein. The assay was performed at 30 °C and at 1,000 rpm. His-tagged PD-1 protein was firstly immobilized onto <t>HIS1K</t> biosensor on Octet RED384. Binders was applied at a concentration of 1 µM as an analyte for association and dissociation steps for 150 seconds and 30 seconds respectively. PA denotes the parent binder. (L) Equilibrium dissociation constant (K d ) of anti-PD-1 binder variants. K d was derived from the association (K a ) and dissociation (K dis ) rate constants measured from the five concentration scan BLI curves. Error bars represent the 95% confidence interval of the fitted K d . Differences in K d were assessed by a two-sided z-test using moving-block bootstrap standard errors of the global fit (85 seconds blocks, 1,000 resamples; Holm-corrected for comparisons). **, p<0.01
Ni Nta Biosensors, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biosensor/Octet+Ni-NTA+(NTA)+Biosensors/pm42883724-205-9-7
Average 97 stars, based on 1 article reviews
ni nta biosensors - by Bioz Stars, 2026-11
97/100 stars
  Buy from Supplier

Image Search Results


TEDs were immobilized on the biosensor through the SpyTag003-SpyCatcher003 reaction. (A) Experimental procedure for the “Assay 1: Binding analysis” ( and ). Biotinylated SpyCatcher003 was immobilized on streptavidin-coated SAX2 biosensors through the biotin-streptavidin interaction, followed by conjugation of SpyTag003-fused TED. (B) Experimental procedure for the “Assay 2: Covalent cross-linking analysis” ( and ). SpyCatcher003 was immobilized on AR2G biosensors through amine-coupling chemistry, followed by conjugation of SpyTag003-fused TED.

Journal: Science Advances

Article Title: Chemically encoded pH-tunable covalent adhesion by a bacterial thioester domain

doi: 10.1126/sciadv.aeg7646

Figure Lengend Snippet: TEDs were immobilized on the biosensor through the SpyTag003-SpyCatcher003 reaction. (A) Experimental procedure for the “Assay 1: Binding analysis” ( and ). Biotinylated SpyCatcher003 was immobilized on streptavidin-coated SAX2 biosensors through the biotin-streptavidin interaction, followed by conjugation of SpyTag003-fused TED. (B) Experimental procedure for the “Assay 2: Covalent cross-linking analysis” ( and ). SpyCatcher003 was immobilized on AR2G biosensors through amine-coupling chemistry, followed by conjugation of SpyTag003-fused TED.

Article Snippet: Streptavidin-coated SAX2 biosensors (Sartorius) were hydrated for 10 min and loaded with 2 μM biotinylated SpyCatcher003-His-Avi for 5 min. To remove loosely bound proteins, the biosensors were regenerated using 10 mM glycine (pH 2.0).

Techniques: Binding Assay, Analysis, Conjugation Assay, Covalent Coupling

TEDs were immobilized on the biosensor through the SpyTag003-SpyCatcher003 reaction. (A) Experimental procedure for the “Assay 1: Binding analysis” ( and ). Biotinylated SpyCatcher003 was immobilized on streptavidin-coated SAX2 biosensors through the biotin-streptavidin interaction, followed by conjugation of SpyTag003-fused TED. (B) Experimental procedure for the “Assay 2: Covalent cross-linking analysis” ( and ). SpyCatcher003 was immobilized on AR2G biosensors through amine-coupling chemistry, followed by conjugation of SpyTag003-fused TED.

Journal: Science Advances

Article Title: Chemically encoded pH-tunable covalent adhesion by a bacterial thioester domain

doi: 10.1126/sciadv.aeg7646

Figure Lengend Snippet: TEDs were immobilized on the biosensor through the SpyTag003-SpyCatcher003 reaction. (A) Experimental procedure for the “Assay 1: Binding analysis” ( and ). Biotinylated SpyCatcher003 was immobilized on streptavidin-coated SAX2 biosensors through the biotin-streptavidin interaction, followed by conjugation of SpyTag003-fused TED. (B) Experimental procedure for the “Assay 2: Covalent cross-linking analysis” ( and ). SpyCatcher003 was immobilized on AR2G biosensors through amine-coupling chemistry, followed by conjugation of SpyTag003-fused TED.

Article Snippet: SpyCatcher003 fused with an N-terminal 6×His (10 μM) was diluted 20-fold into 10 mM sodium acetate (pH 4.5) and immobilized onto AR2G biosensors (Sartorius) preactivated with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide/sulfo– N -hydroxysuccinimide for 2 min. Unreacted esters were quenched with 1 M ethanolamine (pH 8.3).

Techniques: Binding Assay, Analysis, Conjugation Assay, Covalent Coupling

(A) Fixed amino acid residues for MESSI-based deimmunization of LuxSit-i. The structure of LuxSit-i (shown in blue and red) with its luciferin substrate (shown in green) is generated by Alphafold-3. The color on LuxSit-i denotes the number of overlapping NMP-predicted HLA-DRB1*15:01 epitopes at each amino acid position. Fixed amino acid residues are depicted as yellow-colored spheres. (B) Sequence identity of MESSI-generated LuxSit-i variants relative to the parental LuxSit-i. (C) Structural metrics of MESSI-generated LuxSit-i variants. (D) Comparison of epitope density between parental LuxSit-i and a MESSI-generated variant, MESSI-D2. All structures were generated by AlphaFold-3. Color denotes the number of overlapping NMP-predicted HLA-DRB1*15:01 epitopes at each amino acid position. (E) Experimental validation of luminescence from MESSI-generated LuxSit-i variants. Gene fragments encoding the parental and MESSI-designed proteins were synthesized and used as linear DNA template for in vitro RNA transcription and protein translation (IVTT). Afterwards, the reaction product was purified with a nickel spin column to remove the His-tagged IVTT machinery. A final concentration of 25 µM of diphenylterazine (DTZ) was added to the purified proteins. Luminescence was recorded on a plate reader every minute over 2 hr. (F) Peak luminescence recorded within 2 hours after DTZ addition. “No template” denotes the negative control condition where no DNA template was added to the IVTT reaction. Error bars, standard deviation. n = 3 replicates. A two sided unpaired t-test with welch’s correction is calculated between no-target condition and each of the MESSI designs and parent. **, p < 0.01; ****, p < 0.0001. (G) Computational workflow for designing a deimmunized binder against PD-1 using MESSI coupled with BindCraft. In particular, MESSI is inserted at the end of the original BindCraft workflow to replace the soluble MPNN inverse folding model to design sequences against the optimized structures. (H) Structural metrics of MESSI-generated variants of anti-PD-1 binder. (I) Comparison of epitope density between the parental anti-PD-1 binder and a MESSI-generated variant, MESSI-D4. All structures were generated by AlphaFold-3. Blue colors denote a binder region that does not contain NMP predicted epitopes. Red color denotes binder regions with NMP-predicted HLA-DRB1*15:01 epitopes greater than 0. White color denotes the PD-1, the target protein for the designed binder. (J) Strep-tagged minibinders are produced with Genscript IVTT kit. After the production, the binders are purified with streptavidin beads and eluted in 1 mL of PBS. The dot plots show the concentration (expression) fold-change (FC) of the MESSI-generated binders relative to the parental binder designed by BindCraft. (K) Bio-Layer Interferometry (BLI) binding curves for measuring the binding parameters of MESSI-designed anti-PD-1 binders against the target PD-1 protein. The assay was performed at 30 °C and at 1,000 rpm. His-tagged PD-1 protein was firstly immobilized onto HIS1K biosensor on Octet RED384. Binders was applied at a concentration of 1 µM as an analyte for association and dissociation steps for 150 seconds and 30 seconds respectively. PA denotes the parent binder. (L) Equilibrium dissociation constant (K d ) of anti-PD-1 binder variants. K d was derived from the association (K a ) and dissociation (K dis ) rate constants measured from the five concentration scan BLI curves. Error bars represent the 95% confidence interval of the fitted K d . Differences in K d were assessed by a two-sided z-test using moving-block bootstrap standard errors of the global fit (85 seconds blocks, 1,000 resamples; Holm-corrected for comparisons). **, p<0.01

Journal: bioRxiv

Article Title: Protein Deimmunization with a Generative Diffusion Model

doi: 10.64898/2026.10.09.758136

Figure Lengend Snippet: (A) Fixed amino acid residues for MESSI-based deimmunization of LuxSit-i. The structure of LuxSit-i (shown in blue and red) with its luciferin substrate (shown in green) is generated by Alphafold-3. The color on LuxSit-i denotes the number of overlapping NMP-predicted HLA-DRB1*15:01 epitopes at each amino acid position. Fixed amino acid residues are depicted as yellow-colored spheres. (B) Sequence identity of MESSI-generated LuxSit-i variants relative to the parental LuxSit-i. (C) Structural metrics of MESSI-generated LuxSit-i variants. (D) Comparison of epitope density between parental LuxSit-i and a MESSI-generated variant, MESSI-D2. All structures were generated by AlphaFold-3. Color denotes the number of overlapping NMP-predicted HLA-DRB1*15:01 epitopes at each amino acid position. (E) Experimental validation of luminescence from MESSI-generated LuxSit-i variants. Gene fragments encoding the parental and MESSI-designed proteins were synthesized and used as linear DNA template for in vitro RNA transcription and protein translation (IVTT). Afterwards, the reaction product was purified with a nickel spin column to remove the His-tagged IVTT machinery. A final concentration of 25 µM of diphenylterazine (DTZ) was added to the purified proteins. Luminescence was recorded on a plate reader every minute over 2 hr. (F) Peak luminescence recorded within 2 hours after DTZ addition. “No template” denotes the negative control condition where no DNA template was added to the IVTT reaction. Error bars, standard deviation. n = 3 replicates. A two sided unpaired t-test with welch’s correction is calculated between no-target condition and each of the MESSI designs and parent. **, p < 0.01; ****, p < 0.0001. (G) Computational workflow for designing a deimmunized binder against PD-1 using MESSI coupled with BindCraft. In particular, MESSI is inserted at the end of the original BindCraft workflow to replace the soluble MPNN inverse folding model to design sequences against the optimized structures. (H) Structural metrics of MESSI-generated variants of anti-PD-1 binder. (I) Comparison of epitope density between the parental anti-PD-1 binder and a MESSI-generated variant, MESSI-D4. All structures were generated by AlphaFold-3. Blue colors denote a binder region that does not contain NMP predicted epitopes. Red color denotes binder regions with NMP-predicted HLA-DRB1*15:01 epitopes greater than 0. White color denotes the PD-1, the target protein for the designed binder. (J) Strep-tagged minibinders are produced with Genscript IVTT kit. After the production, the binders are purified with streptavidin beads and eluted in 1 mL of PBS. The dot plots show the concentration (expression) fold-change (FC) of the MESSI-generated binders relative to the parental binder designed by BindCraft. (K) Bio-Layer Interferometry (BLI) binding curves for measuring the binding parameters of MESSI-designed anti-PD-1 binders against the target PD-1 protein. The assay was performed at 30 °C and at 1,000 rpm. His-tagged PD-1 protein was firstly immobilized onto HIS1K biosensor on Octet RED384. Binders was applied at a concentration of 1 µM as an analyte for association and dissociation steps for 150 seconds and 30 seconds respectively. PA denotes the parent binder. (L) Equilibrium dissociation constant (K d ) of anti-PD-1 binder variants. K d was derived from the association (K a ) and dissociation (K dis ) rate constants measured from the five concentration scan BLI curves. Error bars represent the 95% confidence interval of the fitted K d . Differences in K d were assessed by a two-sided z-test using moving-block bootstrap standard errors of the global fit (85 seconds blocks, 1,000 resamples; Holm-corrected for comparisons). **, p<0.01

Article Snippet: Binding kinetics were measured by biolayer interferometry (BLI) on an Octet RED384 instrument (Sartorius, Cat. No. FB-20493) using anti-penta-HIS (HIS1K) biosensors (Sartorius, Cat. No. 18-5120) and tilted-bottom 384-well microplates (Sartorius, Cat. No. 18-5166).

Techniques: Generated, Sequencing, Comparison, Variant Assay, Biomarker Discovery, Synthesized, In Vitro, Purification, Concentration Assay, Negative Control, Standard Deviation, Produced, Expressing, Binding Assay, Affinity Constant, Derivative Assay, Blocking Assay